MOXA ioLogik E2240
Active Ethernet I/O 8 Analog Inputs, 2 Analog Outputs
- Instant Event Reporting by TCP/UDP/e-mail/SNMP trap
- Easy Local Control without Programming by Patented Click&Go Logic
- 8-channel analog input for mV, voltage, current signal with wire-off detection (at 4-20mA)
- 2-channel analog output for voltage, current actuator control
- Connecting up to 10 hosts
- SNMP to I/O mapping that works with Network Management System
- Quick programming library for VB, VC, BCB
- Windows VB and Windows/WinCE/Linux C API
- Peer-to-Peer I/O without controller
The ioLogikE2240 is designed for system integrators to acquire and control remote sensors and actuators remotely over TCP/IP and Ethernet networks.
Active Ethernet I/O is an exciting new breed of Ethernet I/O that introduces active I/O messaging with easy logic control. Absolutely no programming is required to configure the I/O server’s control logic, due to the patented and intuitive Click&Go™ interface. Bi-directional and direct input-to-output signal communication over Ethernet is supported, and Windows/Linux APIs are included for use in both industrial automation and IT environments.
Improve system efficiency via real-time data acquisition
Unlike traditional passive remote I/O, Active Remote I/O provides Active I/O messaging that can send message over Ethernet, TCP/IP network on I/O input status changes or meets certain condition, the message is sent to host computer. Communication between the host computer and Active Remote I/O device is concise and efficient. In addition, the message delivery time is 20 times faster than traditional SCADA systems (50 ms compared to 1 sec).
No programming! Hassle-free Click&Go logic control
Click&Go logic is the key to make ioLogik E2000 series become an intelligent remote I/O. Click&Go logic lets you decide when to send I/O data, and what to say to host computers for simple alarm control and messaging.
As opposed to using C-language or PLC-ladder, a person who understands basic logic concepts can do the configuration themselves, and easily finish their projects. Unlike passive remote I/O architecture, you can integrate Active Remote I/O¡¯s input signals into one event to be an integrated message, and set up local output control at the same time. The unique Click&Go logic is a patent pending technology developed by Moxa.
Unique LCD Display Module for on-site configuration
ioLogik E2000 series Active Remote I/O provides an optional LCD display module for on-site management and configuration. The unique display module can display network and I/O settings, e.g. analog input value, digital input counter value. The IP, netmask address can be set locally without carrying a PC.
Independent Configuration for Multi-functional AI and AO points
Each analog input can be independently configured by voltage or current mode by software. The analog input channels support various signals ranging from +/-150 mV to +/-10V at 16-bit resolution.
ioLogik E2240 Specifications
Inputs and Outputs
Analog Inputs
8 channels
Analog Outputs
2 channels
Analog Input
Type
Differential input
Resolution
16 bits
I/O Mode
Voltage / Current
Input Range
±150 mV, ±500 mV, ±5 V, ±10 V, 0 to 20 mA, 4 to 20 mA
Accuracy
±0.1% FSR @ 25°C
±0.3% FSR @ -10 and 60°C
±0.5% FSR @ -40 and 75°C
Sampling Rate
All channels:
- 10 samples/sec for voltage
- 6 samples/sec for current
- 1.25 samples/sec for voltage
- 0.75 samples/sec for current
- 1.25 samples/sec for voltage
- 0.75 samples/sec for current
Input Impedance
900k ohms (min.)
Built-in Resistor for Current Input
120 ohms
Isolation
3k VDC or 2k Vrms
Analog Output
Resolution
12 bits
Output Range
0 to 10 V, 4 to 20 mA
Drive Voltage
15 VDC for current output
Accuracy
±0.1% FSR @ 25°C,
±0.3% FSR @ -10 and 60°C
±0.5% FSR @ -40 and 75°C
Load Resistor
Less than 250 ohms
Power Requirements
Power Consumption
198 mA @ 24 VDC
MTBF (mean time between failures)
Time
155,941 hrs
Database
Telcordia (Bellcore)
Common Specifications
LAN
Ethernet
1 10/100 Mbps RJ45 port
Protection
1.5 kV magnetic isolation
Protocols
Modbus/TCP, TCP/IP, UDP, DHCP, BOOTP, SNMP, HTTP, CGI, SNTP, SMTP
Serial Communication
Interface
RS-485-2w: Data+, Data-, GND (3-contact terminal block)
Serial Line Protection
15 kV ESD for all signals
Serial Communication Parameters
Parity
None
Data Bits
8
Stop Bits
1
Flow Control
None
Baudrate
1200 to 115200 bps
Protocol
Modbus/RTU
Power Requirements
Power Input
24 VDC nominal, 12 to 36 VDC
Physical Characteristics
Wiring
I/O cable max. 14 AWG
Dimensions
115 x 79 x 45.6 mm (4.53 x 3.11 x 1.80 in)
Weight
under 250 g
Mounting
DIN rail or wall
Environmental Limits
Operating Temperature
Standard Models: -10 to 60°C (14 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
Storage Temperature
-40 to 85°C (-40 to 185°F)
Ambient Relative Humidity
5 to 95% (non-condensing)
Altitude
Up to 2000 m
Note Please contact us if you require products guaranteed to function properly at higher altitudes.
Standards and Certifications
Safety
UL 508
EMI
EN 61000-3-2; EN 61000-3-3; EN 61000-6-4;
FCC
Part 15, Subpart B, Class A
EMS
EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6,
EN 61000-4-8, EN 61000-4-11, EN 61000-6-2
Shock
IEC 60068-2-27
Freefall
IEC 60068-2-32
Vibration
IEC 60068-2-6
Green Product
RoHS, CRoHS, WEEE
Ordering Information
Available Modules | |
ioLogik E2240 | Ethernet Micro RTU Controller with 8 analog inputs and 2 analog outputs |
ioLogik E2240-T | Ethernet Micro RTU Controller with 8 analog inputs and 2 analog outputs, -40 to 85°C operating temperature |