Sensor for indirect single-phase measurement of AC current up to 30A without cutting the wire

HW group 30A Current probe 1W-UNI 2
5130_31760.png
5130_31761.png
5130_31762.png
5130_31763.png
  • EigenschaftenEigenschaften
  • BeschreibungBeschreibung
  • Weitere InformationenWeitere Informationen
  • PDFPDF
  • Current range of the transducer: 0–30A
  • Measurement accuracy: 2%
  • Electrical isolation: The 1-Wire UNI bus is electrically isolated from the measured circuit.
  • A/D converter resolution: 16 bits
  • Display resolution: 0.1A
  • Measured voltage: max. 400V
  • Measurement without cutting the measured wire
  • Operating temperature/humidity: 0°C to 40°C (32°F to 104°F), RH < 80%
  • Storage temperature/humidity: -10°C to +50°C (14°F to 122°F), RH < 70%
  • The length of lead wire between the transformer and converter: 1m

30A Current probe 1W-UNI 2 is a sensor for indirect single-phase measurement of AC current up to 30A without cutting the wire. The split-core current transducer can be opened in order to insert a line wire. The sensor is suitable for monitoring power consumption of racks, BTS’s or server rooms. Sensor is suitable for Poseidon and, Ares product family.


Applications and usage:

  • The current transducer (“CLAMP METER”) clamps around the line (L) or neutral (N) wire carrying the measured current.
  • The wire under measurement must be insulated!
  • The “CLAMP METER” and “Converter” must be connected using a double insulated wire.



Together with a Poseidon unit, the sensor can serve as an early warning system against overloading the electricity supply or its individual lines. 30A Current probe 1W-UNI 2 consists of a clamp-on current transducer (CLAMP METER) and a 1-Wire converter unit.
ProdGrafik

SPECIFICATIONS

    Measurement

      Measure
      Current

      Range
      0–30 A

      Accuracy
      ± 2.0

      Resolution
      0.10

      Technology
      Converter

      Cable length:
      3 meter

      Galvanic isolation:
      1

      Units Converter:
      YES

      Calibrated Points:
      8

      Number of values provided:
      1



    Power and dimensions

      Power supply:
      RJ-11 (from 1-Wire)

      Power supply:
      5V

      Consumption:
      10mA

      Operating environment:
      -15°C – 50°C / 0%RH – 80%RH

      Storage environment:
      -30°C – 60°C / 5%RH – 95%RH

      Dimensions:
      26 x 29 x 42 (WxHxD) / 177g



    Type

      Environment:
      SoHo , IT

      Installation:
      Table , Wall

      Protection:
      IP33

      Connectors:
      RJ12

      Design:
      Room