Raritan PX2-1886

SPHINX in Europa
DE
  • AT
  • BE
  • DK
  • FR
  • DE
  • IE
  • IT
  • NL
  • ES
  • SE
  • CH
  • UK
Produktgruppen > Power Management > Raritan PX2-1886

Raritan PX2-1886

Monitored rack power distribution unit
(0U [vertical], 7.4kVA, 36 outlets)

Raritan PX2-1886
6104_19291.png
6104_19292.jpg
6104_19293.jpg
  • BeschreibungBeschreibung
  • Weitere InformationenWeitere Informationen
  • PDFPDF

Monitored rack power distribution unit (0U [vertical], 7.4kVA, 36 outlets).



INPUT:
230v, 32a - IEC 60309 2P+E 6h 32A plug (2P3W);

OUTPUT:
24@ C13, 12@ C19 outlets; on 2@ 1-pole, 16a Overcurrent Protectors;

FEATURES:
Billing-Grade (+/- 1%) Energy Metering [kW, kVA, V, A, Power Factor] - per inlet, per breaker/fuse;
3-digit LED user-selectable display (voltage, current, or active power : per line or per breaker).
Local display of alarms and configuration information(name, ratings, IP/Networking);
Onboard embedded processor with minimum 400MHz clock speed, 16MB NOR Flash, and 64MB SDRAM;
Remote network monitoring via HTML, JSON-RPC, SSH, Telnet, MODBUS/TCP, and SNMPv3.
Environmental monitoring [temp/humidity] capable of up to 32 sensors.
Individual outlet numbers labeled on chassis.
Automated deployment via TFTP, DHCP/PXE, SSH(CLI), or USB Flash Drives.
WiFi Capable.
USB Webcam Capable.
iPad/iPhone/Android App.
Breaker metering and alarming (0V detection).
Max Dimensions 52mm x 53mm x 1780mm (2.1in x 2.1in x 70.1in).
Max Weight 6 kg.
Maximum ambient temperature 50C at full load.
ProdGrafik

Features

    Energy Metering
    Voltage (V), Current (A), Active Power (kW), Real Power (kVA), Energy (kWh), Power Factor

    Metering Accuracy
    ISO/IEC 62053-21 1%

    Remote Outlet Switching
    No

    Metering per input line
    Yes for all models

    Metering per Branch Circuit Breaker
    Yes

    Environmental Sensor Ready
    Yes

    Compatible Sensors
    Temperature, Humidity, Air Flow, Differential Pressure, Water Leak, and Contact Closure.

    Cascading
    Yes, Max 16 PDUs can be daisy chained using a USB connection.
    Note: Firmware version 3.3.10 or above is required.

    Networking
    10/100/1000 BaseT Ethernet.
    Optional WiFi (802.11a/b/g/n).

    Onboard Display
    3-digit LED user-selectable display (voltage, current, or active power : per line or per breaker).
    Auto-flip orientation




Specifications

    Input

      Input Plug
      IEC 60309 2P+E 6h 32A (2P3W)

      Nominal Voltage
      230V

      Maximum Input Current
      32A

      Rated Input Current
      32A

      Power Capacity
      7.4kVA

      Cord Length
      3m



    Output

      Nominal Voltage
      230V

      Receptacles (Output Connections)
      (24) IEC320 C13
      (12) IEC320 C19

      Overload Protection
      (2) Airpax LEGBX6-37483-16-V



    Physical

      Dimensions (WxDxH)
      2.1in x 2.1in x 70.1in; 52mm x 53mm x 1780mm

      Unit Weight
      6 kg

      Shipping Weight
      8.5 kg

      Shipping Dimensions
      285mm x 115mm x 1915mm

      Mounting
      Tool-less Button Mount



    Environmental

      Operating Temperature/Environment
      50 C

      Operating Relative Humidity
      85%

      Operating Elevation
      0-10000ft



    Conformance

      Regulatory Approvals
      CE



Kunden, die diesen Artikel gesehen haben, sahen auch
Alle Cookies akzeptieren Ablehnen Konfigurieren

Diese Website verwendet Cookies, um eine bestmögliche Erfahrung bieten zu können. Mehr erfahren.