Advantech ADAM-6066

SPHINX in Europa
DE
  • AT
  • BE
  • DK
  • FR
  • DE
  • IE
  • IT
  • NL
  • ES
  • SE
  • CH
  • UK
Produktgruppen > I/O Modules > Advantech ADAM-6066

Advantech ADAM-6066

6-ch Digital Input and 6-ch Power Relay Modbus TCP Module

Advantech ADAM-6066
1070_14295.png
1070_7533.png
1070_7534.png
1070_14297.gif
  • EigenschaftenEigenschaften
  • BeschreibungBeschreibung
  • Weitere InformationenWeitere Informationen
  • PDFPDF
  • 6-ch DI, 6-ch RL, Ethernet-based smart I/O
  • Remote monitoring and control with mobile devices
  • Group configuration capability for multiple module setup
  • Flexible user-defined Modbus address
  • Intelligent control ability by Peer-to-Peer and GCL function
  • Active I/O message by data stream or event trigger function
  • Multiple protocol support: Modbus TCP, TCP/IP, UDP, HTTP, DHCP
  • Web language support: XML, HTML 5, Java Scrip
ADAM-6000 modules are empowered by peer-to-peer (P2P) and Graphic Condition Logic (GCL), and can perform as standalone products for measurement, control and automation. Instead of having additional controllers or programming, system configurations can be done in an extremely short time with the easy-to-use and intuitive graphic utility.

Group Configuration Capability for Multiple Module Setup
To aid configuration and save time, engineers can configure and upgrade the firmware of multiple ADAM-6000s simultaneously

Remote Monitoring and Control with Smart Phone
With support for HTML5, the ADAM-6000 can be monitored and controlled from any browser on mobile devices whilst in the field and when the engineer is connected to their network.

Advanced Security and High Reliability
ADAM-6000 Ethernet I/O modules have fast response time, and advanced security and reliability. When communication is broken, the digital output module can generate pre- defined values to ensure safety.

Peer-to-Peer
Modules will actively update the input channel status to specific output channels. Without dealing with the trouble of long distance wiring, users can define the mapping between a pair of modules.

Graphic Condition Logic
Users can define the control logic rules through graphical configuration Utility, and download defined logic rules to specific ADAM module. Then, it will execute the logic rules automatically just like a standalone controller.


The Advantech ADAM-6066’s six digital output channels are designed for 240 V AC, 5 A ratings, and support both dry contact and pulse output. Besides, ADAM-6066 has an embedded web server for remote monitoring, supports Modbus/TCP and UDP protocol to meet standard communication requirements, and offers personalized settings for improved flexibility. Its watchdog timer and host idle functions secure communication for reliable operation.
ProdGrafik
Digital Input

Channels
6

Dry Contact
Logic level 0: close to GND
Logic level 1: open

Wet Contact
Logic level 0: 3 V DC
Logic level 1: 10 ~ 30 V DC

Supports 3 kHz Counter Input (32-bit + 1-bit overflow)

Keep/Discard Counter Value when Power-off

Supports 3 kHz Frequency Input

Supports Inverted DI Status


Relay Output (Form A)

Channels
6

Contact Rating (Resistive)
250 V AC @ 5 A, 30 VDC @ 3 A

Breakdown Voltage
500 V AC (50/60 Hz)

Relay On Time
7 ms

Relay Off Time
3 ms

Total Switching Time
10 ms

Insulation Resistance
1 G Ω min. at 500 V DC

Maximum Switching Rate (at rated load)
20 operations/minute

Supports Pulse Output


General

LAN
10/100Base-T(X)

Power Consumption
2.5 W @ 24 V DC

Connectors
RJ-45 (Ethernet),Plug-in screw terminal block (I/O and power)

Watchdog
System (1.6 second) and Communication (programmable)

Power Input
10 ~ 30 V DC

Dimensions (W x H x D)
70 x 122 x 27 mm

Enclosure
PC

Mounting
DIN 35 rail, stack, wall

Supports Peer-to-Peer, GCL

Supports User Defined Modbus Address

Supports Modbus/TCP, TCP/IP, UDP, DHCP and HTTP Protocols


Protection

Power Reversal Protection

Isolation Protection
2,000 V DC


Environment

Operating Temperature
-20 ~ 70°C (-4 ~ 158°F)

Storage Temperature
-30 ~ 80°C (-22 ~ 176°F)

Operating Humidity
20 ~ 95% RH (non-condensing)

Storage Humidity
0 ~ 95% RH (non-condensing)


Software

.NET Class Library (SDK)
    Windows and Windows CE Class Library, VB and VC# Sample Code for I/O Reading or Configuration and Communication

Adam/Apax .NET Utility
    Network Setting, I/O Configuration, Data stream, P2P, GCL Configuration


Ordering Information

ADAM-6066           6-ch DI and 6-ch Power Relay Modbus TCP Module


Accessories

PWR-242           DIN-rail Power Supply (2.1A Output Current)
PWR-243 Panel Mount Power Supply (3A Output Current)
PWR-244 Panel Mount Power Supply (4.2A Output Current)


Software

PCLS-ADAMVIEW32           ADAMView Data Acquisition Software
PCLS-OPC/MTP30 OPC Server for Modbus/TCP protocol


Kunden, die diesen Artikel gesehen haben, sahen auch
Alle Cookies akzeptieren Ablehnen Konfigurieren

Diese Website verwendet Cookies, um eine bestmögliche Erfahrung bieten zu können. Mehr erfahren.