HW group Sensor 60V 1W-UNI v2

SPHINX in Europa
DE
  • AT
  • BE
  • DK
  • FR
  • DE
  • IE
  • IT
  • NL
  • PL
  • ES
  • SE
  • CH
  • UK
Produktgruppen > Environmental Sensors > HW group Sensor 60V 1W-UNI v2

HW group Sensor 60V 1W-UNI v2

Measuring voltage from 0 to 60V DC (-48V DC)

HW group Sensor 60V 1W-UNI v2
5135_16393.png
5135_11939.jpg
5135_11940.png
5135_11941.png
  • EigenschaftenEigenschaften
  • BeschreibungBeschreibung
  • Weitere InformationenWeitere Informationen
  • PDFPDF
  • Electrically isolated input. Negative voltages from 0 to –60VDC can be also measured.
  • High accuracy (can be used for 0–10V, too).
  • Sensors can be daisy-chained (two RJ11 connectors).
  • Powered from the 1-Wire UNI bus (RJ11) or from an external power adapter.

Electrically isolated voltage sensor for up to 60VDC with 1Wire-UNI output. Typical applications include measuring voltage at industrial sensors (0-10V) or battery voltage. Frequently used for -48 volt power supply measurement in telecommunications (-48V standard). Voltage can be monitored over LAN (Poseidon2) or GSM (Ares).

Signal converter for DC voltage measurement (up to 60V DC) with conversion to the 1-Wire UNI bus (RJ11). Typically used as a power or battery voltage sensor in telco applications (-48V standard). Also useful for voltage sensing at the output of a 0-10V industrial transducer, including unit conversion.

The voltage sensor can be connected to Poseidon2 or Ares units. The values can be shared over LAN or GSM.

When the voltage is out of a specified range, e-mail or SMS is sent. Can be connected to remote monitoring systems that are based on SNMP or Modbus/TCP.


Applications

  • Battery voltage monitoring in telecommunication systems (telco –48V)
  • Independent measurement of individual battery cells (electrically isolated)
  • 12V or 24V car battery voltage sensor
  • Signal converter for 0-10V industrial sensors
  • DC current sensor in -48V systems (with a current sensing resistor)


ProdGrafik

Specification

Bus
Type 1Wire-UNI (RJ11)
Connects to Poseidon2 xxxx, Ares xx, Poseidon 2250, Poseidon 4002, SiteMon5
Connector 2x RJ11 (sensors can be daisy-chained)
Maximum distance 60m (total line length from the active port)
Electrical isolation 1Wire-UNI bus is electrically isolated from the 0-60V input
Power
Power supply 1Wire-UNI bus + external power adapter
External power 5VDC external power adapter can be used
Power limits One active RJ11 port can power at most two sensors.
To boost the power, use our “1-Wire hub Power” or an external power adapter.
Electrical isolation 0-60V input electrically isolated from the 1Wire-UNI (RJ11)
Sensor input
Connector 2-pin terminal block ( V+ , V-)
Measures Electrical voltage 0 to 60VDC (0-1V, 0-10V, -48V DC, 0-60V)
Input range 0 to 60VDC (max. 70V)
Accuracy 2% of the full 60V range / 25°C
Sensor output
Resolution 1 decimal place
Displayed units Default: [V]
If you need a conversion (e.g. to [m], [mm], [hPa], [ppm]), contact your distributor.
Measuring period Once per second
Miscellaneous
Operating conditions -40 to +85 °C (-40 to +185 °F) / 5 to 70% RH
Dimensions / mass 65 x 80 x 30 [mm] / 200 g



Remote -48V DC voltage monitoring over a LAN (SNMP)

  • 60V voltage sensor measures voltage from a DC UPS (48VDC rated voltage).
  • DC voltage sensor is connected to a Poseidon2 3266 remote monitoring LAN unit over 1-Wire UNI (RJ11) bus.
  • Sensor 60V 1W-UNI v2 is powered from the 1-Wire UNI (RJ11) bus. Additional sensors can be daisy-chained to this sensor.
  • The power to the "Sensor 60V 1W-UNI v2" can be boosted with an external 5V power adapter.

  • Poseidon2 3266 displays the external voltage readings in its web interface.
  • Poseidon2 3266 sends an e-mail or a text message (SMS) when the voltage is outside of a specified "SafeRange".
  • Poseidon2 3266 shares data over the LAN using SNMP, XML (http) and Modbus/TCP.
  • Poseidon2 3266 can be connected to the SensDesk.com online portal.
  • Sensor readings can be displayed using an Android or iOS (Apple) app for tablets or mobile phones.



GSM monitoring of current and voltage in a 48VDC system

  • The upper 60V voltage sensor measures voltage from a DC UPS (48VDC rated voltage).
  • The lower sensor measures voltage at a current sensing resistor. This voltage is proportional to the current that passes through the resistor.
  • The "Sensor 60V 1W-UNI v2" sensors are daisy-chained and connected to the Ares unit over the 1-Wire UNI bus (RJ11) bus.
  • The internal Ares battery provides back-up power to both sensors.

  • Ares 12 is a GSM/GPRS unit for remote measurement and monitoring.
  • Ares 12 sends an e-mail or a text message (SMS) when the voltage and/or current is outside of a specified "SafeRange".
  • The DC current sensor can be configured to convert the reading to amps [A].

  • Ares 12 can be connected to the SensDesk.com online portal.
  • Sensor readings can be displayed using an Android or iOS (Apple) app for tablets or mobile phones.



Ordering

Sensor 60V 1W-UNI v2 DC voltage sensor (converter) with a 0 to 60V DC input and a 1-Wire UNI (RJ11) output.
Recommended for -48V DC power supply measurement, electrically isolated.
Can be connected to Ares and Poseidon2 units.
Sensor 60V 1W-UNI Converter with a 0 to 60V DC input and a 1-Wire UNI (RJ11) output.
Older model with lesser accuracy – replaced by "Sensor 60V 1W-UNI v2".



Kunden, die diesen Artikel gesehen haben, sahen auch
Alle Cookies akzeptieren Ablehnen Konfigurieren

Diese Website verwendet Cookies, um eine bestmögliche Erfahrung bieten zu können. Mehr erfahren.