MultiTech Conduit IP67 200 Series
IP67 Base Station for Outdoor LoRa® Deployments
- Greatly expands LoRa network coverage
- External antenna increases LoRa connectivity to remote assets
- Improved design enhancing thermal performance and easy external port access to SIM and USB connectors
- ISM band scanning for optimum LoRa performance
- GNSS for location coordinate information
- Certified for North American 915 MHz and Europe 868 MHz ISM bands
MultiTech Conduit® IP67 200 Series Base Station is a ruggedized IoT gateway solution, specifically designed for outdoor LoRa® public or private network deployments. This highly scalable and certified IP67 solution is capable of resisting the harshest environmental factors including moisture, dust, wind, rain, snow and extreme heat, supporting LoRaWAN® applications in virtually any environment. The enhanced Conduit IP67 solution can support thousands of LoRaWAN certified end nodes, including the MultiTech mDot? and xDot®. This flexible solution provides durable, low-power, wide area connectivity in support of M2M and IoT applications for both LoRa service providers and individual enterprises wanting to expand their LoRa network coverage.
Designed for easy deployment, the solution includes an IP67 enclosure, extgernal LoRa antenna to improve outdoor range and Ethernet or optional 4G-LTE backhaul.
It can be deployed as part of an existing telecommunications tower, individual stand or wall mount.
Designed for easy deployment, the solution includes an IP67 enclosure, extgernal LoRa antenna to improve outdoor range and Ethernet or optional 4G-LTE backhaul.
It can be deployed as part of an existing telecommunications tower, individual stand or wall mount.
HARDWARE OVERVIEW
Connectors | ||
Interface | Label | Connector Type |
SIM Card | SIM | 3FF Micro SIM |
USB Host | None | Type A USB Connector |
Ethernet Port | RJ-45 Jack | |
Ground Lug | 7/16 HEX 1/4 x 20 Stainless Steel | |
Vent Valve | S-Flange | |
Antenna Connectors | ||
Interface | Label | Connector Type |
LoRa Antenna | 1 | N-Type Antenna Connector |
Cellular Antenna (primary) | None | Internal antenna. No external interface |
GNSS Antenna | ||
GNSS Antenna |
HARDWARE SPECIFICATIONS
Feature | Description | ||
CPU Module | ARM9 processor with 32-Bit ARM & 16-Bit Thumb instruction sets ? 400 MHz ? 16K Data Cache ? 256 MB Flash Memory ? 16K Instruction Cache ? 128X16M DDR RAM | ||
WAN Backhaul Options | Ethernet | 10/100 Base T | All Models |
Cellular | LTE Category 4 | -LNA3 models only | |
GNSS (location, time stamping) | GNSS for LoRa Packet Time Stamping Concurrent GNSS connections: 3 GNSS Systems Supported: (default: concurrent GPS/QZSS/SBAS and GLONASS) GNSS antenna: Internal to chassis | ||
LEDs | STATUS, LORA, CELL | ||
Input Power | Ethernet Input Power: 37 - 57 VDC provided by PSE injector with power rating of 25W or greater | ||
Power-over-Ethernet (PoE) | PoE Standard: IEEE 802.3at | ||
Power Draw | See Hardware Guide for current draw at specified voltages. | ||
Physical Description | |||
Dimensions (L x W x H) | 6" x 6" x 4" (152.4 mm x 152.4 mm x 101.6 mm) (see diagram) | ||
Weight | Approximately 3 lbs (1.4 kg) | ||
Chassis | Type IP67-Rated composite | ||
Mounting Options | Wall mount built into chassis (see diagram) / Pole mount (accessory required) | ||
Environmental | |||
Operating Temperature | -40° C to +70° C | ||
Storage Temperature | -40° C to +85° C | ||
Certifications and Approvals | |||
EMC Compliance | ROHS Directive 2011/65/EU EN 50581:2012 RED Directive 2014/53/EU. Article 3.1b (EMC) EN 301 489-1 V2.1.1 (General) | ||
Radio Certifications | RED Directive 2014/53/EU. Article 3.2 (Radio) | ||
Quality | MIL-STD-810G: High Temp, Low Temp, Random Vibration. SAE J1455: Transit Drop & Handling Drop, Random Vibration, Swept-Sine Vibration. IEC68-2-1: Cold Temp. IEC68-2-2: Dry Heat | ||
Safety | Low Voltage Directive (LVD) 2014/35/EU Article. 3.1a IEC 60950-1 2nd Edition + Am2:2013 EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011 + A2:2013 IEC 62368-1:2014 (Second Edition), EN 62368-1:2014 + AC:2017 (Second Edition) EN 62311:2008 (MPE/RD Exposure) |
LORAWAN WAN SPECIFICATIONS
- LoRa Module
- Frequency Band
868 MHz
Channel Plan
EU868
Power Output*
14 dBm
RX Range
863 ? 873 MHz
TX Range
863 ? 873 MHz
Sensitivity
*Maximum output power before antenna / 1x8 channel / Half-Duplex
EMC Compliance
- ROHS Directive 2011/65/EU EN 50581:2012
RED Directive 2014/53/EU. Article 3.1b (EMC)
EN 301 489-1 V2.1.1 (General)
EN 301 489-3 V2.1.1 (LoRa/SRD)
Radio Compliance
- EN 300 220-2 V3.1.1 (LoRa/ISM Radio)
CELLULAR WAN SPECIFICATIONS
Available Modules / Accessories | |
Models | MTCDTIP2-L4E1 |
Cellular Performance | 4G - LTE Category 4 |
Cellular Fallback | 3G - HSPA+, 2G - GPRS |
Frequency Band (MHz) | 4G: B1(2100), B3(1800), B7(2600), B8(900), B20(800), B28A(700) 3G: B1(2100), B3(1800), B8(900) 2G: B3(1800), B8(900) |
Packet Data (LTE FDD) | Up to 150 Mbps downlink, Up to 50 Mbps uplink |
SIM Card | (1) 3FF Micro SIM |
Antenna Connector | Primary and diversity: Internal to chassis |
Mobile Network Operator (MNO) Approvals | GCF Certified Cell Module. European Network Operators |
EMC Compliance | CE Mark, IEC 60950-1 |
Radio Compliance | Draft EN 301 489-52 V1.1.0 (Cellular) EN 301 511 V12.5.1 (GSM) EN 301 908-1 V11.1.1 (IMT Cellular) |
ORDERING INFORMATION
Available Modules Ethernet Only Models | |
MTCDTIP2-EN-B11EKP-D1M | Ethernet only mPower Programmable Base Station, 8-channel, 868 MHz with internal LoRa antenna ? Ethernet ? Internal LoRa Antenna ? GNSS |
MTCDTIP2-EN-B11EKP-L1M | Ethernet only mPower Programmable Base Station, 8-channel, 868 MHz with external LoRa antenna ? Ethernet ? External LoRa Antenna ? GNSS ? Accessory Kit |
LTE Category 4 Models | |
MTCDTIP2-L4E1-B11EKP-D1M | LTE Cat 4 mPower Programmable Base Station, 8-channel, 868 MHz with internal LoRa antenna, internal cellular antenna ? Cellular ? Internal LoRa Antenna ? GNSS |
MTCDTIP2-L4E1-B11EKP-D1M | LTE Cat 4 mPower Programmable Base Station, 8-channel, 868 MHz with external LoRa antenna, internal cellular antenna ? Cellular ? External LoRa Antenna ? GNSS ? Accessory Kit |
RECOMMENDED ACCESSORIES MultiTech Conduit® IP67 200 Series Base Station | |
PS-56V-POE-EU-1 | Single Port 30W Power over Ethernet Transformer (Class A) with European Power Cord (1 Pack) |
PS-56V-POE-EU-5 | Single Port 30W Power over Ethernet Transformer (Class A) with European Power Cord (5 Pack) |
PS-56V-POE-GB-1 | Single Port 30W Power over Ethernet Transformer (Class A) with European Power Cord (1 Pack) |
PS-56V-POE-GB-5 | Single Port 30W Power over Ethernet Transformer (Class A) with European Power Cord (5 Pack) |
MTKIT-IP67-MF | Conduit IP67 Accessory Kit (includes antenna mounting bracket, coax cable, two clamps and lightning arrestor) |
LGT-ARRST-1 | Conduit IP67 Base Station Lightning Arrestor (1 Pack) |
LGT-ARRST-5 | Conduit IP67 Base Station Lightning Arrestor (5 Pack) |
CA-NTYPE-MF-1 | Outdoor Coax Cable, N Type Male & Female connectors, 5 feet (1 Pack) |
CA-NTYPE-MF-5 | Outdoor Coax Cable, N Type Male & Female connectors, 5 feet (5 Pack) |
MB-ANT-IP67-1 | Conduit IP67 Antenna Mounting Bracket, Mounts One Antenna (1 Pack) |
MB-ANT-IP67-5 | Conduit IP67 Antenna Mounting Bracket, Mounts 1 Antenna (5 Pack) |
AN868-915A-1-IP67 | IP67 LoRa Antenna, 15.3" (4.5 dBi) (1 Pack) |
AN868-915A-5-IP67 | IP67 LoRa Antenna, 15.3" (4.5 dBi) (5 Pack) |
MTKIT-POLEMOUNT-2 | Pole Mount Kit, for 2 inch diameter poles (for MTCDTIP2-xx models) |
MTKIT-POLEMOUNT-3 | Pole Mount Kit, for 3 inch diameter poles (for MTCDTIP2-xx models) |
MTKIT-POLEMOUNT-4 | Pole Mount Kit, for 4 inch diameter poles (for MTCDTIP2-xx models) |
MTKIT-POLEMOUNT-10-12 | Pole Mount Kit, for 10 - 12 inch diameter (for MTCDTIP2-xx models) |
Kunden, die diesen Artikel gesehen haben, sahen auch