AKCP Current Transformers (CTXXXX)

Current Transformers are designed for easy installation with a simple, fast, safe and easy way to connect a monitoring system to your power supply

AKCP Current Transformers (CTXXXX)
4003_27028.png
4003_27029.png
  • BeschreibungBeschreibung
  • Weitere InformationenWeitere Informationen
  • PDFPDF
AKCess Pro Current Transformers are designed for easy installation with a simple, fast, safe and easy way to connect a monitoring system to your power supply.

  • Sensing Overload Currents
  • Ground fault detection
  • Metering
  • Analog to Digital circuits
  • Facilities and building management


AKCess Pro provide split core current transformers that can be installed without opening any cable or bus bar circuit. The connection of conventional Current Transformers (CTs) usually requires the interruption of the primary side circuit to pass cables or bus bars through the transformer core or to connect such cables to the primary terminals.

The AKCess Pro transformers core can be easily opened and installed then connected without any supply interruption. AKCess Pro Current Transformers save you time and installation costs and are safer to work with :

  • Compact size for easy mounting
  • Wide inner window, allowing clamping of big cables or bus bars
  • Wide range of sizes to accommodate all existing installations
  • High accuracy and reliability


The AKCess Pro CTs connect to the securityProbe and has its own interface so you can set parameters for monitoring and alerting on a variety of measurement factors.

ProdGrafik
Connect to AKCP securityProbe5E

The AKCP CT?s connect to the securityProbe and securityProbe 5E units. When connected to the securityProbe the unit has its own interface that allows you to set parameters for monitoring and alerting on a variety of measurement factors.

If a pre-set parameter is reached the securityProbe can trigger an alert or complete an action, e.g. Email, SMS, MMS, Fax, Switch/Relay or even make a Telephone call.

These CT?s connect to the ?CT? type AKCP Power Monitor Sensor which in turn then connects to the AKCP securityProbe unit.



Specifications

Primary current :
  • 100A-5000A

Secondary current :
  • 5A, 1A

Standard approval :
  • IEC44-1, BS7626

Maximum voltage :
  • 0.72/3Kv

Frequency :
  • 50/60Hz

Rated load :
  • 1VA-30VA

Class :
  • 0.5, 1.0, 3.0

Short-time thermal current :
  • 1th=100xln

Rated security coefficient :
  • FS<5





Ordering Information

    Product Model         Order Number     Description
Split Core Current Transformer
(CT only not including meter)
CTXXX/5A   From 100/5A to 400/5A    
CTXXX/5A   From 500/5A to 800/5A
CTXXX/5A   From 1000/5A to 4000/5A
Split Core Current Transformer
(With 0-5VDC Output for use with A2D)
CTXXX/5V   From 5A/5V to 50A/5V
CTXXX/5V   From 10A/5V to 100A/5V
CTXXX/5V   From 100A/5V to 300A/5V
CTXXX/5V   From 100A/5V to 500A/5V    
Note: XXX is number of Amps required